    New IRDH275B-435 Bender Ground Fault Detector / Insulation Monitor
    New
    IRDH275B-435
    Manufacturer:
    Bender
    Manufacturer Part Number: IRDH275B-435
    Original Packaging:  Yes
    Instructions: Yes
    Nominal Voltage Un:    AC 0...793V /DC 0...650 V
    Supply Voltage US:      AC 88...264 / DC 77...286 V
    ISOMETER® IRDH27
    Insulation monitoring device for AC and DC IT systems
    Application main circuits with connected frequency converters
    According to IEC 61557-8
    Automatic adaptation to the system leakage capacitance
    Info button to display the device setting
    The ISOMETER® of the IRDH275 series is designed to monitor the insulation resistance of unearthed main circuits (IT systems) AC, AC / DC 0…793 V resp. DC 0…650 V. The
    AMP
    Plus
    measuring principle meets the particular requirements of modern power supplies which often include rectifiers, converters, thyristor-controlled DC drives and directly connected DC components. In these systems often high leakage capacitances against earth occur due to interference suppression measures. The IRDH275 automatically adapts itself to the existing system conditions.
    In combination with a coupling device, the Isometers can also be used for higher voltages. An external supply voltage allows de-energized systems to be monitored too. For door mounting into distribution panels, refer to type IRDH375(B).
    Features:
    Insulation monitoring for unearthed AC, AC/DC systems 0…793 V, DC 0…650 V
    Nominal voltage extendable via coupling device
    Two separately adjustable response values1 kΩ…10 MΩ
    AMP
    Plus
    measurement method
    Automatic adaptation to the system leakage capacitance
    Info button to display device settings and system leakage capacitance
    Self monitoring with automatic alarm
    Automatic self test, selectable
    Connection for external kΩ indication
    Test and reset button
    Connection external test/reset button
    Two separate alarm relays with two voltage-free changeover contacts
    N/O or N/C operation
    Backlit LC display
    RS-485 interface